Staircase to the loft
Storyboard
The opening in the floor of the attic, built with SIP panels, was constructed differently from the original design, complicating the installation of the future staircase. However, with an appropriate cut, it can be adjusted to create a suitable opening.
ID:(151, 0)
Opening assembly error
Description
The design for accessing the attic includes a narrow spiral staircase, as it is only used when accessing the storage room or the attic for hobbies. It was designed to turn counterclockwise:
However, upon observing the assembly, it is evident that it differs from the original design:
ID:(935, 0)
Origin of the problem
Description
The source of the problem is that piece A19 was mounted in reverse, resulting in the end of the staircase being parallel to the walkway:
To solve the problem, the direction of the staircase ascent can be reversed.
ID:(936, 0)
Correction of the assembly
Description
To solve the problem, the platform needs to be adjusted so that the axis of the staircase is centered. This will center the corner of the platform, making it possible to correctly mount the staircase:
This can be achieved by removing a 5-centimeter-wide element from the edge of the platform:
ID:(937, 0)